  june, 10th 2010 automotive grade AUIR3317(s) low emi current sense high side switch features ? load current feedback www.irf.com 1 ? over current shutdown ? active clamp ? esd protection ? input referenced to vcc ? over temperature shutdown ? switching time optimized for low emi ? reverse battery protection description the AUIR3317(s) is a fully protected 4 terminals high side switch. the input signal is referenced to vcc. when the input voltage vcc - vin is higher than the specified threshold, the output power mosfet is turned on. when the vcc - vin is lower than the specified vil threshold, the output mosfet is turned off. a current proportional to the power mosfet current is sourced to the ifb pin. either over current and over temperature latches off the switch. the device is reset by pulling the input pin high. other integrated protections (esd, reverse battery, active clamp) make the switch very rugged in automotive environment. product summary rds(on) 7 m ? max. vcc op. 6 to 26v current ratio 8800 over-current 120a vclamp 40v package to-220 d2pak AUIR3317 pin 4 and 5 fused AUIR3317s typical connection out AUIR3317s in rifb vcc load battery input power ground ifb logic ground current feeback 10k on off
AUIR3317(s) qualification information ? automotive (per aec-q100 ?? ) qualification level comments: this family of ics has pass ed an automotive qualification. ir?s industrial and consumer qualification level is granted by extension of the higher automotive level. d2pak-5l msl1, 260c (per ipc/jedec j-std-020) moisture sensitivity level to220-5l not applicable machine model class m4 (450v) (per aec-q100-003) human body model class h3a (4,500 v) ( per aec-q100-002 ) esd charged device model class c4 (1000 v) (per aec-q100-011) ic latch-up test class ii, level a (per aec-q100-004) rohs compliant yes ? qualification standards can be found at international rectifier?s web site http://www.irf.com/ ?? exceptions to aec-q100 requirement s are noted in the qualification report. www.irf.com 2
AUIR3317(s) absolute maximum ratings absolute maximum ratings indicate sustained limits beyond which damage to the device may occur. all voltage parameters are referenced to vcc lead. (tj=-40..150c, vcc=6..26v tambient=25c unless otherwise specified). symbol parameter min. max. units vcc-vin maximum vcc voltage -16 37 vcc-vin cont. maximum continuous vcc voltage -16 26 vcc-vfb maximum ifb voltage -16 33 vcc-vout maximum output voltage -0.3 37 v ids cont. maximum body diode continuous cu rrent rth=60c/w (1) tambient=25c ? 2.8 ids pulsed maximum body diode pulsed current (1) ? 100 a pd maximum power dissipati on rth=60c/w tambient=25c ? 2 w tj max. max. storage & operating temperature junction temperature -40 150 c min rfb minimum on the re sistor on ifb pin 0.3 ? k ? ifb max. max. ifb current -50 50 ma (1) limited by junction temperature. pulsed is also limited by wiring thermal characteristics symbol parameter typ. max. units rth1 thermal resistance junction to ambient d2-pak std footprint 60 ? rth2 thermal resistance junc tion to case d2-pak 0.7 ? rth2 thermal resistance junction to case to220 0.7 ? c/w recommended operating conditions these values are given for a quick design. for operation ou tside these conditions, please consult the application notes. symbol parameter min. max. units continuous output current tambient=85c, rth= 5c/w, tj=125c 23 iout tambient=85c, rt h=60c/w, tj=125c ? 7 a pulse min. minimum turn-on pulse width 1 ? ms fmax. maximum operating frequency ? 200 hz www.irf.com 3
AUIR3317(s) protection characteristics tj=-40..150c, vcc=6..26v symbol parameter min. typ. max. units test conditions tsd over temperature threshold ? 165 ? c see fig. 5 ov over voltage protection (not latched) 26 29 33 v isdf fixed over current shutdown 90 120 150 a treset time to reset protection ? 50 500 see fig. 5 min. pulse min. pulse width (no wait state) ? 900 2000 s tj=25c wait wait function timer 0. 4 1 2 ms see fig. 4 and 5 reverse battery on state resistance tj=25c 4 6.7 10 rds(on) rev. tj=125c ? 10 15 m ? vcc-vin=-14v, iout=30a static electrical characteristics tj=-40..150c, vcc=6..26v (unless otherwise specified) symbol parameter min. typ. max. units test conditions vcc op. operating voltage range 6 ? 26 v icc off supply leakage current ? 1.5 5 a vin=vcc, vcc-vout=14v, vcc-vifb=14v, tj=25c iin, on on state in positive current 1.5 3 6 ma vcc-vin=14v, tj=25c vih high level input threshold voltage (4) ? 5.4 6.3 vil low level input threshold voltage (4) 4 4.9 5.8 vhyst input hysteresis vih-vil 0.2 0.4 1.5 v iout drain to source leakage current ? 1.2 5 a vin=vcc, vcc-vifb=0v, vcc-vout=14v, tj=25c on state resistance (5) tj=25c 4 5.5 7 iout=30a, vcc-vin=14v on state resistance (5) tj=25 c 4 6 10 iout=17a, vcc-vin=6v rds(on) on state resistance (5 )(6) tj=150c 7 10.5 13.5 m ? iout=30a, vcc-vin=14v v clamp1 vcc to vout clamp voltage 1 36 39 ? iout=50ma v clamp2 vcc to vout clamp voltage 2 ? 40 43 v iout=30a, tj=25c (4) input thresholds are measured direct ly between the input pin and the tab. any parasitic resistance in common between the load current path and the input signal path can significantly affect the thresholds. (5) rdson is measured between the tab and the out pin, 5mm away from the package. (6) guaranteed by design switching electrical characteristics vcc=14v, resistive load=0.5 ? , tj=25c symbol parameter min. typ. max. units test conditions tdon turn on delay time to 10% vcc 30 120 300 tr1 rise time to vcc-vout=5v 20 50 125 tr2 rise time to vcc-vout=0.1vcc 30 80 200 s eon turn on energy ? 14 ? mj tdoff turn off delay time 30 140 350 tf fall time to vout=10% of vcc 35 100 250 s eoff turn off energy ? 7 ? mj see figure 2 www.irf.com 4
AUIR3317(s) current sense characteristics tj=-40..150c, vcc=6..26v (unless otherwise specified) symbol parameter min. typ. max. units test conditions ratio i load/iifb current ratio 8,200 8,800 9,950 ? rfb=500 ? , iout=60a ratio_tc i load/iifb variation aver temperature(6) -5 ? +5 % tj=-40c to 150c offset load current diagnostic o ffset -0.2 0 +0.25 a iout=2a trst ifb response time (low signal) ? 1 ? s 90% of the iout step functional block diagram all values are typical 1 ms 3ma charge pump fast turn-off driver reverse battery protection in ifb out vcc on /of f set reset latch q timer 43v 80 ? + - tj > 165c iout > 120a 400s timer - + 29v 38v 43v - + 43v wait m in. pulse www.irf.com 5
AUIR3317(s) lead assignments 1- in 2- ifb 3- vcc (tab) 4- out 5- out 1 2 4 5 d2pak 3- vcc 1 2 3 4 5 to220 3- vcc 1- in 2- ifb 3- vcc (tab) 4- nc 5- out vou t vcc-vin tr-in 90% 10 % 90% 10 % td on tr1 td off tf vc c-5v tr2 vcc-vin vih vil vhyst iin icc ifb in vcc out ir3317 ifb vcc-vout vclamp1 vclamp2 iout isd figure 1 ? voltages and current definitions figure 2 ? switching time definitions www.irf.com 6
AUIR3317(s) figure 3 ? active clamp waveforms figure 4 ? min. pulse and wait function figure 5 ? protection timing diagrams v ou t ut n io vi t clamp vcc-vin t min. pulse iout t min. pulse wait vcc vcc - v clamp se e a pp lication notes to evaluate p ower dissi p ation vcc-vin t < t reset iout wait t j t > t reset over-current shutdown t < t reset wait t > t reset over-temperature shutdown www.irf.com 7
AUIR3317(s) www.irf.com 8 all curves are typical characteristics. operation in ha tched areas is not recommended. tj=25c, rifb=500ohm, vcc=14v (unless otherwise specified). 0 2 4 6 8 10 0 102030405 0 1 2 3 4 5 6 -50 0 50 100 150 icc off, supply leakeage current (a) icc, supply current (ma) 0 vcc-vin, supply voltage (v) tj, junction temperature (c) figure 6 ? icc (ma) vs vcc-vin (v) figure 7 ? icc off (a) vs tj (c) 0 1 2 3 4 5 6 -50-25 0 25 50 75100125150 vih vil 50% 100% 150% 200% -50 0 50 100 150 rds(on), drain-to -source on resistance (normalized) vih, and vil (v) tj, junction temperature (c) tj, junction temperature (c) figure 8 - normalized rds(on) (%) vs tj (c) figure 9 ? vih and vil (v) vs tj (c)
AUIR3317(s) www.irf.com 9 0 10 20 30 -50 0 50 100 150 60c/w 35c/w figure 10 ? error (+/- a) vs i load (a) rifb, feedback resistor ( ? ) error (+/-a) 10 100 100 1000 10000 figure 11 ? ids (a) vs rifb ( ? ) isd, over current shutdown (a) 0 2 4 6 8 10 12 14 16 18 0 2040608010 0 with calibration spec. max. i load, load current (a) 10 100 10 100 1000 max. output current (a) max. output current (a) tamb., ambient temperature (c) inductance (h) figure 12 ? max. iout (a) vs tamb. (c) figure 13 ? max. iout (a) vs inductance (h)
AUIR3317(s) www.irf.com 10 0.1 1 10 100 1.e-4 1.e-3 1.e-2 1.e-1 1.e+0 1.e+1 1.e+2 50c/w free air 5c/w 10 100 1.e-01 1.e+00 1.e+01 1.e+02 1.e+03 tamb=25c tamb=100c zth, transient thermal impedance (c/w) ids, output current (a) protection response time (s) time (s) figure 14 ? ids (a) vs over temperature protection response time (s) figure 15 ? transient thermal impedance (c/w) vs time (s)
AUIR3317(s) case outline - to220 - 5 leads www.irf.com 11
AUIR3317(s) case outline - d2pak ? 5 leads www.irf.com 12
AUIR3317(s) tape & reel - d2pak ? 5 leads www.irf.com 13
AUIR3317(s) part marking information ordering information standard pack base part number package type form quantity complete part number to220 ? 5leads tube 50 AUIR3317 tube 50 AUIR3317s tape and reel left 800 AUIR3317strl AUIR3317 d2pak ? 5leads tape and reel right 800 AUIR3317strr www.irf.com 14
AUIR3317(s) important notice unless specifically designated for the automotive market, inte rnational rectifier corporation and its subsidiaries (ir) reserve the right to make corrections, modifications, enhancem ents, improvements, and other changes to its products and services at any time and to discontinue any product or servic es without notice. part numbers designated with the ?au? prefix follow automotive industry and / or customer spec ific requirements with regards to product discontinuance and process change notification. all products are sold subject to ir?s terms and conditions of sale supplied at the time of order acknowledgment. ir warrants performance of its hardware products to the specifications applicable at the time of sale in accordance with ir?s standard warranty. testing and other quality control techniques are used to the extent ir deems necessary to support this warranty. except where mandated by government requirements, testing of all parameters of each product is not necessarily performed. ir assumes no liability for applications assistance or customer pr oduct design. customers ar e responsible for their products and applications using ir co mponents. to minimize the risks with customer products and applications, customers should provide adequate design and operating safeguards. reproduction of ir information in ir data books or data sheets is permissible only if reproduction is without alteration and is accompanied by all associated warranties, conditions, limit ations, and notices. reproduction of this information with alterations is an unfair and deceptive business practice. ir is not responsible or liable for such altered documentation. information of third parties may be subject to additional restrictions. resale of ir products or serviced with statements different fr om or beyond the parameters stated by ir for that product or service voids all express and any implied warranties for the associated ir product or service and is an unfair and deceptive business practice. ir is not res ponsible or liable for any such statements. ir products are not designed, intended, or authorized for use as components in systems intended for surgical implant into the body, or in other applications intended to support or sustain life, or in any other application in which the failure of the ir product could create a situation where personal injury or death may occur. should buyer purchase or use ir products for any such unintended or unauthorized application, buyer shall indemnify and hold international rectifier and its officers, employees, subsidiaries, affiliates, and distributors harmless against all claims, costs, damages, and expenses, and reasonable attorney fees arising out of, directly or indirectly, any claim of personal injury or death associated with such unintended or unauthorized use, even if such claim alleges that ir was negligent regarding the design or manufacture of the product. ir products are neither designed nor int ended for use in military/aerospace applic ations or environments unless the ir products are specifically designated by ir as military-grade or ? enhanced plastic.? only pr oducts designated by ir as military-grade meet military specifications. buyers acknowl edge and agree that any such use of ir products which ir has not designated as military-grade is solely at the buyer?s risk, and that they are solely respons ible for compliance with all legal and regulatory requirements in connection with such use. ir products are neither designed nor intended for use in autom otive applications or environments unless the specific ir products are designated by ir as compliant with iso/ts 16949 requirements and bear a part number including the designation ?au?. buyers acknowledge and agree that, if they use any non-designated products in automotive applications, ir will not be responsible for any failure to meet such requirements. for technical support, please contact ir?s technical assistance center http://www.irf.com/technical-info/ world headquarters: 233 kansas st., el segundo, california 90245 tel: (310) 252-7105 www.irf.com 15
AUIR3317(s) www.irf.com 16 revision history revision date notes/changes a first release b 10/06/2010 au release


▲Up To Search▲   

 
Price & Availability of AUIR3317

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X